Häufig gestellte Fragen

HVAC-Systeme
WHY IS SPECTROLINE TRUSTED BY MORE OEMS THAN ANY OTHER BRAND?

Spectronics Corporation invented fluorescent leak detection in 1955. Today, we are the world’s leading manufacturer of ultraviolet equipment and fluorescent leak detection dye. Spectroline products are OEM-grade, co-solvent free, NSF certified, and can safely remain within AC&R systems.

HOW DO I USE FLUORESCENT LEAK DETECTION DYE?

Simply add our patented fluorescent dye to the suspect system. Let the dye circulate. Once the dye has permeated the system, scan for leaks with one of our high-intensity leak detection flashlights. All leak sites will glow brightly with escaping fluorescent dye, even pinhole leaks and intermittent ones.

HOW LONG DOES IT TAKE TO FIND A LEAK?

In kleinen bis mittelgroßen Systemen können Sie Lecks innerhalb von Minuten finden. In kommerziellen Systemen kann es einige Stunden dauern, bis der Farbstoff vollständig zirkuliert. Fügen Sie zur vorbeugenden Wartung Spectroline-Farbstoff hinzu, lange bevor Sie ein Problem haben. Ein Techniker kann innerhalb von Sekunden eine Inspektion durchführen, wenn der Farbstoff bereits Zeit hatte, vollständig zu zirkulieren.

ARE FLUORESCENT DYES SYSTEM SAFE?

Spectroline® fluorescent leak detection dye is engineered to be fully-miscible. It is, by definition, a non-particulate and is filtered down to 2 microns. This ensures the fluorescent dye doesn’t change the precise characteristics of the host fluid. Lubricity, viscosity, and other properties of the original host fluid are completely unaffected when dye is added to the system. Spectroline® fluorescent dyes are also NSF-certified, meaning they are not harmful to the environment and went through rigorous testing.

WHY IS DYE CONCENTRATION IMPORTANT?

Dye fluorescence is dependent on the ratio of fluorescent material to carrier oil. Poor performing dyes typically have low levels of fluorescent material. Simply put, poor dyes lack the concentration necessary to provide an effective fluorescent response. Spectroline dyes are concentrated and able to fluoresce all leak areas brightly. This means Spectroline dyes are more economical because less dye is used per application.

WHAT ARE CO-SOLVENTS AND HOW DO THEY ALTER SYSTEM PERFORMANCE?

Co-solvents are chemical substances added to increase the solubility of specific compounds. This means co-solvents harmfully change the original lubricant properties of refrigerant oil. Co-solvents can lead to premature wear and outright damage. Poorly manufactured fluorescent dyes typically contain high levels of co-solvents. In addition to changing system properties, co-solvents have the potential to deteriorate system metals.nance protocol.

WHAT TYPE OF OIL/LUBRICANT DOES THE DYE WORK IN?

Our core dye products are Universal/POE formula. For AC&R systems using PVE lubricant we have specific dyes for those: SPE-GS1PVE-P6, SPE-GS2PVE-P6, SPE-GS3PVE-P6.

WHICH INJECTION METHOD SHOULD I USE?

For HVAC/R Systems- EZ-Ject™ is our patented multi-dose injection method and GLO-STICK® is our direct inject, single-dose method that has varing concentration strengths. Both are suited for small-to-medium sized AC&R systems – such as residential units, ice machines, window units, and refrigerators.
BigEZ™ is our injection method for medium-to-large sized AC&R systems – e.g., commercial units, supermarket units, refrigerated warehouses, food and dairy plants, and industrial facilities. Review our product dosage information for the correct application.

WHICH FLUORESCENT DYE COLOR DO I SELECT FOR MY INDUSTRIAL SYSTEM?

Spectroline® offers a variety of dye colors that are engineered to best suit specific host fluids and fluid power applications. Use different colors to detect leaks across multiple systems. Color-code each system to ensure fluid power leaks are found quickly and with immediate certainty.

WHAT DO YOU MEAN BY “ECO-FRIENDLINESS” OF THE FLUORESCENT DYES?

We care about your health as well as the health of our planet. The materials used in the dyes consist of completely organic-free fibers. It makes our leak detection dyes different from conventional dyes that have co-solvents. Due to its materials, after half a year in the ground our dyes will fully degrade without any harm to nature. The second important thing is that we do not use any chemically aggressive liquids, which can damage one’s health. And finally, UV lamps consume only 10W, which equals to the power of a simple light bulb. In this day and age, energy saving not only has economic benefits, but also enables us to reduce consumption of natural resources as well as emission of harmful substances into the atmosphere.

WHAT IS SPECIFIC ABOUT SPECTROLINE LAMPS VS. A COMPETITOR?

Spectroline leak detection lamps are specifically designed for leak detection application only. Competitor lamps consist of various numbers of LEDS and the manufacturer designed it with many different applications in mind, leak detection not being the main focus.

CAN FLUORESCENT LEAK DETECTION DYES BE SEEN WITHOUT A UV LAMP?

We reccomend using a Spectroline leak detection lamp for best results when searching for leaks and in low-light conditions.

WHAT IS THE TEMPRETURE RANGE OF OUR AC DYES?

(-80C to 250C)

WHAT IS THE TEMPRETURE RANGE OF OUR AC SEALANTS?

(-40C TO 200C)

HOW MUCH CAN LEAK DETECTION SAVE ME?

Es gibt viele Faktoren, die bestimmen, wie viel Sie sparen können, außerdem kann es als vorbeugendes Wartungsprotokoll dienen.

WHERE CAN I FIND MORE DTEAILED INFORMATION ABOUT THE FULL PRODUCT LINE?

Unsere fluoreszierenden und UV-Produkte finden Sie hier.